Fluke 89 IV True RMS Digital Multimeter 89IV 89-4 89-IV

$ 366.96

Availability: 100 in stock
  • Form Factor: Handheld
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • MPN: Does not apply
  • Restocking Fee: No
  • Features: Backlight
  • Test/Measurement Functions: AC Voltage
  • Condition: Seller refurbished
  • Brand: Fluke
  • Return shipping will be paid by: Buyer
  • Display: Analog
  • Model: 89 IV

    Description

    ebay template
    The Following Items Are Included:
    Fluke 89 IV True RMS Digital Multimeter (BC# 32493-L/T*)
    (2) 1000V Hard Point Test Leads
    User Manual On CD-ROM
    Carrying Case (G)
    BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS!
    Fluke 89 IV True RMS Digital Multimeter
    Includes Carrying Case & Accessories As Listed Above!
    Working Condition: Excellent
    Condition: Refurbished
    Claibrated: Yes
    Warranty: 1 YEAR WARRANTY
    The top-of-the line Fluke 89 Series IV, in stand-alone operation, can log up to 1000 measurements. The PC interface allows for further analysis and documentation using optional FlukeView ™ software. It sounds like a lot to get in one DMM. But what else do you expect from Fluke?
    Nominal Specifications
    Function
    Ranges/Description
    DC Voltage
    0 to 1000V
    DC Current
    0 to 10A (20A for 30 seconds)
    AC Voltage, True-rms
    15 mV to 1000V - 100 kHz bandwidth
    AC Current, True-rms
    25 μA to 10A (20A for 30 seconds)
    Resistance
    0 to 30 Mohms
    Conductance
    0 to 50 Nanosiemens
    Capacitance
    0.01 nF to 50 mF
    Diode Test
    3.1V
    Temperature
    -200°C to 1350°C (-328°F to 2462°F)
    Frequency
    0.5 Hz to 1000 kHz
    Accuracy (Basic DC V)
    0.025%
    (Basic AC V)
    0.4%
    Features
    Feature
    Description
    Dual Displays
    50,000 count primary display 5,000 count secondary display
    Backlight with 2 brightness selections
    Bright white backlight for clear readings in poorly lighted areas
    Fast Autorange
    Meter automatically selects best range -instantly
    AC+DC True RMS, ac rms specified to 100 kHz
    Choices for AC only, AC and DC dual display, or AC+DC readings
    dBm, dBV
    User selectable impedance references for dBm
    AutoHOLD
    Uses Touch Hold® feature to capture readings
    Continuity/Open Test
    Beeper sounds for Ohms readings below threshold or for momentary open circuit indication
    Fast Bar Graph
    51 Segments for peaking and nulling
    Duty Cycle/Pulse Width
    Measure time a signal is on or off in % or milliseconds
    MIN MAX/Fast MIN MAX with elapsed and Real Time Stamp
    Record Maximum, Minimum, and Average values. Real Time for MAX or MIN, elapsed time for AVG. Fast MIN MAX captures peaks to 250 msec.
    Closed Case Calibration
    No internal adjustments needed
    Battery/Fuse Access Door
    Battery or fuse replacement without voiding calibration
    Hi-Impact Overmold Case
    Integrated Protective Holster provides superior impact protection for your meter
    Detailed Specifications
    Accuracy is specified for a period of one year after calibration, at 18°C to 28°C (64°F to 82°F) with
    relative humidity to 90%. Accuracy specifications are given as ±([% of reading] + [number of least
    significant digits])
    Function
    Range
    Resolution
    Accuracy
    45 Hz-1 kHz
    20 Hz-45 Hz
    1 kHz-10 kHz
    10 kHz-20 kHz
    20 kHz-100 kHz
    AC mV
    500.00 mV
    0.01 mV
    0.4% + 40
    2% + 80
    5% + 40
    5% + 40
    6% + 40
    3000.0 mV
    0.1 mV
    0.4% + 40
    2% + 80
    0.4% + 40
    1.5% + 40
    6% + 40
    AC V
    5.0000V
    0.0001V
    0.4% + 40
    2% + 80
    0.4% + 40
    1.5% + 40
    6% + 40
    50.000V
    0.001V
    0.4% + 40
    2% + 80
    0.4% + 40
    1.5% + 40
    6% + 40
    500.00V
    0.01V
    0.4% + 40
    2% + 80
    0.4% + 40
    Not specified
    Not specified
    1000.0V
    0.1V
    0.4% + 40
    2% + 80
    0.4% + 40
    Not specified
    Not specified
    dBV
    -56 to -6
    0.01 dB
    0.1 dB
    0.2 dB
    0.5 dB
    0.5 dB
    0.5 dB
    -6 to +34
    0.01 dB
    0.1 dB
    0.2 dB
    0.1 dB
    0.2 dB
    0.5 dB
    +34 to +60
    0.01 dB
    0.1 dB
    0.2 dB
    0.1 dB
    Not specified
    Not specified
    Accuracy
    Function
    Range
    Resolution
    45 Hz-1 kHz
    20 Hz-45 Hz
    1 kHz-20 kHz
    20 kHz-100 kHz
    AC mA
    500.00 μA
    0.01 μA
    0.75% + 20
    1% + 20
    0.75% + 20
    6% + 4
    5.000 μA
    0.1 μA
    0.75% + 5
    1% + 5
    0.75% + 10
    2% + 40
    AC mA
    50.000 mA
    0.001 mA
    0.75% + 20
    1% + 20
    0.75% + 20
    9% + 40
    400.00 mA
    0.01 mA
    0.75% + 5
    1% + 5
    1.5% + 10
    4% + 4
    AC A
    5.0000A
    0.0001A
    1.5% + 20
    1.5% + 20
    6% + 40
    Not specified
    10.000A
    0.001A
    1.5% + 5
    1.5% + 5
    5% + 10
    Not specified
    Function
    Range
    Resolution
    DC
    Accuracy Dual Display AC or AC+DC
    20 Hz-45 Hz
    45 Hz-1 kHz
    1kHz-20 kHz
    DC mV
    500.00 mV
    0.01 mV
    0.03% + 2
    2% + 80
    0.6% + 40
    6% + 40
    3000.0 mV
    0.1 mV
    0.025% + 5 (89-IV) 0.025% + 10 (87-IV)
    2% + 80
    0.6% + 40
    DC V
    5.0000V
    0.0001V
    0.025% + 10
    2% + 80
    0.5% + 40
    50.000V
    0.001V
    0.03% + 3
    2% + 80
    0.5% + 40
    500.00V
    0.01V
    0.1% + 2
    2% + 80
    0.5% + 40
    Not specified
    1000.0V
    0.1V
    0.1% + 2
    2% + 80
    0.5% + 40
    Not specified
    DC mA
    500.00 mA
    0.01 mA
    0.25% + 20
    7% + 10
    7% + 10
    9% + 40
    5.000 mA
    0.1 mA
    0.25% + 2
    1% + 10
    0.75% + 10
    2% + 40
    DC mA
    50.000 mA
    0.001 mA
    0.15% + 10
    1% + 10
    0.75% + 10
    2% + 40
    400.00 mA
    0.01 mA
    0.15% + 2
    1.5% + 10
    1.5% + 10
    3% + 40
    DC A
    5.0000A
    0.0001A
    0.5% + 10
    7% + 20
    7% + 20
    12% + 40
    10.000A
    0.001A
    0.5% + 2
    1.5% + 10
    1.5% + 10
    3% + 40
    Accuracy is specified for a period of one year after calibration, at 18°C to 28°C (64°F to 82°F) with relative humidity to 90%. Accuracy specifications are given as ±([% of reading] + [number of least significant digits])
    Function
    Range
    Resolution
    Accuracy
    Resistance
    500.00W
    0.01W
    0.05% + 10
    5.0000 kW
    0.0001 kW
    0.05% + 2
    50.000 kW
    0.001 kW
    0.05% + 2
    500.00 kW
    0.01 kW
    0.05% + 2
    5.0000 MW
    0.0001 MW
    0.15% + 4
    30.000 MW
    0.001 MW
    1% + 4
    Conductance
    50.00 nS
    0.01 nS
    1% + 10
    Capacitance
    1.100 nF
    0.001 nF
    1% + 5
    11.00 nF
    0.01 nF
    110.0 nF
    0.1 nF
    1.100 mF
    0.001 mF
    11.00 mF
    0.01 mF
    110.0 mF
    0.1 mF
    1,100 mF
    1 mF
    11.0 mF
    0.01 mF
    50.00 mF
    0.01 mF
    Diode Test
    3.1000V
    0.0001V
    2% + 2
    Frequency
    500.00 Hz
    0.01 Hz
    ± (0.005% + 1)
    5.0000 kHz
    0.0001 kHz
    50.000 kHz
    0.001 kHz
    999.99 kHz
    0.01 kHz
    Duty Cycle
    10 to 90%
    0.10%
    ± (0.12 x Voltage Range/ Input Voltage x 100%)
    Pulse Width
    5.0000 ms
    0.0001 ms
    ± (0.0001 ms + 1)
    50.000 ms
    0.001 ms
    Temperature
    -200 to +1350°C
    0.1°C
    ± (1% of reading + 1°C)
    -328 to +2462°F
    0.1°F
    ± (1% of reading + 1.8°F)
    Min-Max-Avg
    Response: 100 ms to 80%
    Specifed accuracy ± 12 counts for changes >200 ms in duration (± 40 digits in AC for changes >350 ms and inputs >25% of range)
    Fast Min-Max
    250 ms
    Specified accuracy ± 100 counts for changes >250 ms in duration
    Interval LOGGING
    At least 288 intervals (specified by user in Setup) may be recorded to internal memory. These values may be viewed using the VIEW MEM function on the meter. Up to 700 unstable event values (similar to AutoHold) are automatically added to LOGGING memory for viewing only through the optional FlukeView® Forms PC software. Additional intervals will be logged if the signal is stable.
    Reading SAVE
    Up to 100 readings may be saved by the user in a memory separate from LOGGING memory. These readings may be viewed using VIEW MEM.
    Frequency Counter Sensitivity
    Input Range
    Minimum Sensitivity (RMS Sine Wave)
    Approximate Trigger Levels
    (DC Voltage Function)
    20 kHz
    40 Hz
    500 kHz
    50 mV (dB only)
    10 mV
    15 mV
    15 mV
    ± 25 mV
    500 mV
    100 mV
    50 mV
    30 mV
    35 mV ± 6 mV
    5000 mV
    1000 mV
    2000 mV
    2000 mV
    170 mV ± 6 mV
    5V
    1V
    2V
    2.2V
    1.7V ± 0.25V
    50V
    10V
    15V
    5V
    3.5V ± 2.5V
    500V
    100V
    50V
    50V
    35V ± 25V
    1000V
    200V
    250V
    50V
    35V ± 25V
    Input Impedance
    Function
    Input Impedance (Nominal)
    Volts, mV
    10 MΩ, < 100 pF
    Common Mode Rejection Ratio (1 kΩ Unbalanced)
    Normal Mode Rejection
    DC Volts, mV
    >100 dB -dc, 50 Hz, or 60 Hz ± 0.1%
    >90 dB at 50 Hz, or 60 Hz ± 0.1%
    AC Volts, mV
    > 90 dB dc to 60 Hz
    Open Circuit Test Voltage
    Full-Scale Voltage
    To 5 MΩ
    30 MΩ + nS
    Ohms
    < 5V
    500 mV
    3.1V
    Diode Test
    < 5V
    3.1000V
    Typical Short-Circuit Current
    500Ω
    5 kΩ
    50 kΩ
    500 kΩ
    5 MΩ
    30 MΩ
    Ohms
    100 μA
    100 μA
    10 μA
    1 μA
    0.1 μA
    0.1 μA
    Diode Test
    0.8 mA typical
    Burden Voltage (A - mA - μA)
    Function
    Range
    Burden Voltage (typical)
    mA -μA
    500.00 μA
    102 μV/μA
    5.000 μA
    102 μV/μA
    50.000 mA
    1.8 mV/mA
    400.00 mA
    1.8 mV/mA
    A
    5.0000A
    0.04 V/A
    10.000A
    0.04 V/A
    For full Fluke 98 IV product specifications, please click here:
    Fluke 89 IV
    Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
    Ebay Test Equipment Store
    . All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
    contact us
    for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
    Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
    We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
    We Ship World Wide!
    We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
    Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
    We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
    We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
    Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
    Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
    A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
    Thank you
    ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
    Sell Smarter with
    Kyozou
    .
    Inventory and Ecommerce Management