-40%
FLUKE 18B+ F18B+ Digital Multimeter AC/DC Voltage Ohm Current LED Test Meter
$ 79.19
- Description
- Size Guide
Description
Please note: This thermometer is made by Fluke in China.The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support!
Fluke 18B+ Capacitance Resistance
Digital Multimeter
Please note: This meter is made by FLUKE in China. Everything is from original FLUKE except the carrying bag which is FREE to you.
Please note:
1.This multimeter includes batteries. Sometimes, due to Customs regulations,
a plastic film is wrapped outside the batteries in the battery
jar.
Please remove the plastic film before using.
2.This meter is made by FLUKE manufacturer in China. Now China Fluke manufactures don't provide printed English user manual. The meter comes with an English user manual printed by us.
You can also download English user manual online: http://assets. fluke. com/manuals/151718__umeng0000.pdf
New Feature:
Faster response
Greater capacitance
range: 0.01nF ~ 1000μF
The more bright:
Add
white LED backlight
Larger screen:
Larger than the original
1.5 times
General Specifications:
Maximum Voltage between any Terminal and Earth Ground: 1000 V
Display(LCD)..................................................4000 counts,updates 3/sec
Battery Type...................................................2 AA,NEDA 15A, IEC LR6
Battery life.......................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)
Temperatuer
Operating.........................................................0 deg to 40 deg
Storage.............................................................-30 deg to 60 deg
Relative Humidity
Operating Humidity.......................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg
Operating Humidity,40MC Range..............≤80% at 10deg to 30deg;≤70% at 30deg to 40deg
Altitude
Operating.........................................................2000m
Storage.............................................................12.000m
Temperature Coefficient..............................0.1×(specified accuracy)/deg(<18deg or > 28deg)
Fuse protection for current inputs............440 mA,1000 V Fast Fuse, Fluck specified part only.
11A,1000v Fast Fuse, Fluke specified part only.
Size(H×W×L)...................................................183×91×49.5(mm)
Weight..............................................................455g
IP Rating..........................................................IP 40
Safety...............................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2
Electromagnetic Environment...................IEC 61326-1:Portable
E
lectromagnetic Compatibility..................Applies to use in Korea only
Class A Equipment(Industrial Broadcasting and Communication Equipment)
AC and DC Voltage
Function
Range
Resolution
Accuracy
15B+
17B+
18B+
AC Volts
(40Hz-500Hz)
[1]
4.000V
40.00V
400.0V
1000V
0.001V
0.01V
0.1V
1V
1.0 % + 3
1.0 % + 3
1.0 % + 3
AC Millivolts
400.0mV
0.1mV
3.0 % + 3
3.0 % + 3
3.0 % + 3
DC Millivolts
400.0mV
0.1mV
1.0 % + 10
1.0 % + 10
1.0 % + 10
DC volts
4.000V
40.00V
400.0V
1000V
0.001V
0.01V
0.1V
1V
0.5 % + 3
0.5 % + 3
0.5 % + 3
[1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
AC and DC current
Function
Range
Resolution
Accuracy
15B+
17B+
18B+
AC Current μA
(40 Hz-400Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
1.5 % + 3
1.5 % + 3
AC current Ma
(40Hz – 400Hz)
40.00 m
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
1.5 % + 3
1.5 % + 3
AC current A
[1]
(40Hz – 400Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
1.5 % + 3
1.5 % + 3
DC current μA
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
1.5 % + 3
1.5 % + 3
DC current mA
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
1.5 % + 3
1.5 % + 3
DC current A
[1]
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
1.5 % + 3
1.5 % + 3
[1] 10 A duty cycle < minutes on, 20 minutes off.
Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle
Function
Range
Resolution
Accuracy
15B+
17B+
18B+
Diode Test
[1]
2.000V
0.001V
10 %
Temperature
50.0°
C
-400.0°
C
0°
C
-50.0°
C
-55.0°
C
-0°
C
0.1°C
NA
2 % +1°
C
2°
C
9% +2°
C
NA
Resistance
(Ohms)
400.0
Ω
4.000KΩ
40.00KΩ
400.0KΩ
4.000MΩ
40.00MΩ
0.1
Ω
0.001KΩ
0.01KΩ
0.1KΩ
0.001MΩ
0.01MΩ
0.5%+3
0.5%+2
0.5%+2
0.5%+2
0.5%+2
1.5%+3
0.5%+3
0.5%+2
0.5%+2
0.5%+2
0.5%+2
1.5%+3
0.5%+3
0.5%+2
0.5%+2
0.5%+2
0.5%+2
1.5%+3
Capacitance
[2]
40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001μF
0.01μF
0.1μF
1μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
Frequency
[3]
(10Hz -100kHz)
Hz
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
0.1%+3
0.1%+3
Duty Cycle
[2]
1% to 99%
0.1 %
NA
1%typical
[4
]
1% typical
[4]
[1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA
[2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range).
[3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified.
[4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %.
LED Test and Continuity Threshold
Function
Lighting Range
Measurement Range
Resolution
Accuracy
LED
V
F
Test
[1]
(
LED Test Socket
)
1.00 to 6.00 V
NA
NA
NA
LED
V
F
Test
[
2]
(
Test leads
)
1.00 to 6.00V
1.00 to 6.00V
0.01V
10%
[3]
Continuity Threshold
NA
NA
NA
NA
[1]
Open circuit test voltage is
±12V and short-circuit current is<±5mA(typical)
[2] Open circuit test voltage is±12V and short-circuit current is<
±3mA(typical)
[3]
V
F
Measurement with driving current under2.2
±0.4 m
A
Input Characteristics
Function
Overload Protection
Input Impedance
(Nominal)
Common Mode
Rejection Ratio
Normal Mode
Rejection Ratio
AC Volts
1000V
[1]
>10MΩ,
50Hz or 60Hz
_
AC Millivolts
400mV
>1MΩ,<100pF
>80dB at dc,
50Hz or 60 Hz
_
DC Volts
1000V
[1]
>10MΩ,<100pF
>100dB at dc,
50Hz or 60 Hz
>60dB at
50Hz or 60 Hz
DC Millivolts
400mV
>1MΩ,<100pF
>80dB at ac,
50 Hz or Hz
_
[1]10
6
V Hz Max
Please note:
Including battery in the package shipped to UK, Spain, Germany, India, Italy, Malaysia, Singapore, Thailand, France and USA.
No battery for other countries.
This meter is made by FLUKE manufacturer in China. Now China Fluke manufacturers don't provide printed English user manual. The meter comes with an English user manual printed by us.
You can also download English user manual online:
http://assets.fluke.com/manuals/151718__umeng0000.pdf
Standard Accessories
(please note: everything in this package is from original FLUKE except the carrying bag which is FREE to you):
1. A Pair of Original Test leads
2. F18B+ meter
5. Batteries.