-40%

FLUKE 15B+ F15B+ Auto Range Digital Probe Multimeter Meter

$ 52.26

Availability: 300 in stock
  • Custom Bundle: No
  • Condition: New
  • Display: Digital
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Seller
  • MPN: F15B+
  • Brand: Fluke
  • Features: Auto-Ranging
  • Modified Item: No
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Model: 15B+
  • Type: Multimeter
  • Restocking Fee: No
  • Non-Domestic Product: No

    Description

    FLUKE 15B+ F15B+ Auto Range Digital Probe Multimeter Meter
    Feature:
    LED backlight
    Larger screen: 1.5 times of F15B's
    Faster response time than F15B
    Date Hold Function
    Both Auto range and Manual range Selectable
    Over range protection for all ranges
    Polarity Indication: Indicates negative polarity
    Overflow Indication
    Sleep Mode /Auto Power off / Low Battery Indication
    Continuity Test with Alert
    Diode Test
    Power Supply: 2 x AA 1.5V Battery (include)
    General Specifications:
    Maximum Voltage between any Terminal and Earth Ground: 1000 V
    Display(LCD).......................................................4000 counts,updates 3/sec
    Battery Type..........................................................2 AA,NEDA 15A, IEC LR6
    Battery life.............................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)
    Temperature
    Operating..............................................................0 deg to 40 deg
    Storage.................................................................-30 deg to 60 deg
    Relative Humidity
    Operating Humidity.............................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg
    Operating Humidity,40MC Range....................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg
    Altitude
    Operating..............................................................2000m
    Storage.................................................................12.000m
    Temperature Coefficient....................................0.1×(specified accuracy)/deg(<18deg or > 28deg)
    Fuse protection for current inputs....................440 mA,1000 V Fast Fuse, Fluck specified part only.
    11A,1000v Fast Fuse, Fluke specified part only.
    Size(H×W×L)........................................................183×91×49.5(mm)
    Weight....................................................................455g
    IP Rating................................................................IP 40
    Safety.....................................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2
    Electromagnetic Environment..........................IEC 61326-1:Portable
    Electromagnetic Compatibility.........................Applies to use in Korea only
    Class A Equipment(Industrial Broadcasting and Communication Equipment)
    ACCURACY SPECIFICATION:
    Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy
    specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
    Function
    Range
    Resolution
    Accuracy
    Model 15B+
    Model 17B+
    AC Volts (40 to 500 Hz)
    400.0 mV 1
    0.1 mV
    3.0 % + 3
    3.0 % + 3
    4.00 V
    40.00 V
    400.00 V
    1000.00 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    1.0 % + 3
    1.0 % + 3
    DC Millivolts M
    400.0 mV
    0.1 mV
    1.0 % + 10
    1.0 % + 10
    DC Volts V
    4.000 V
    40.00 V
    400.0 V
    1000 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    0.5 % + 3
    0.5 % + 3
    Diode Test
    2.000 V
    0.001 V
    10 %
    Temperature
    50 °C to 400 °C
    0 °C to 50 °C
    -55 °C to 0 °C
    0.1 °C
    NA
    2 % + 1 °C
    ± 2 °C
    9 % + 2 °C
    Resistance (Ohms)
    400.0 ω
    4.000 kω
    40.00 kω
    400.0 kω
    4.000 Mω
    40.00 Mω
    0.1 ω
    0.001 kω
    0.01 kω
    0.1 kω
    0.001 Mω
    0.01 Mω
    0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5 % + 3
    Capacitance
    50.00 nF
    500.0 nF
    5.000 µF
    50.00 µF
    100.0 µF
    1000.0µF
    0.01 nF
    0.1 nF
    0.001 µF
    0.01 µF
    0.1 µF
    1µF
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    Frequency Hz (10 Hz -100 kHz)
    50.00 Hz
    500.0 Hz
    5.000 kHz
    50.00 kHz
    100.0 kHz
    0.01 Hz
    0.1 Hz
    0.001 kHz
    0.01 kHz
    0.1 kHz
    NA
    0.1 % + 3
    Duty Cycle
    0.1 % to 99.9 %
    0.1%
    NA
    1% typical
    Function
    Range
    Resolution
    Accuracy
    Model 15B+
    Model 17B+
    AC Current (40 to 200 Hz)
    400.0 µA
    0.1 µA
    1.5 % + 3
    1.5 % + 3
    4000 µA
    1 µA
    AC Current (40 to 200 Hz)
    40.00 mA
    0.01 mA
    1.5 % + 3
    1.5 % + 3
    400.0 mA
    0.1 mA
    AC Current (40 to 200 Hz)
    4.000 A 10.00 A
    0.001 A 0.01 A
    1.5 % + 3
    1.5 % + 3
    DC Current
    400.0 µA
    0.1 µA
    1.5 % + 3
    1.5 % + 3
    4000 µA
    1 µA
    DC Current
    40.00 mA
    0.01 mA
    1.5 % + 3
    1.5 % + 3
    400.0 mA
    0.1 mA
    DC Current
    4.000 A
    0.001 A
    1.5 % + 3
    1.5 % + 3
    10.00 A
    0.01 A
    Function
    Overload Protection
    Input Impedance (Nominal)
    Common Mode Rejection Ratio
    Normal Mode Rejection
    AC Volts V
    1000 V
    >10 Mω <100 pF
    >60 dB at dc, 50 or 60 Hz
    _
    DC Volts V
    1000 V
    >10 Mω <100 pF
    >100 dB at dc, 50 or 60 Hz
    >60 dB at 50 or 60 Hz
    STANDARD ACCESSORIES
    1. FLUKE F15B+ meter
    2. A Pair of Original Test leads TL75
    3. Batteries
    4. Original User Manual