-40%
Fluke 1503 Handheld Digital Insulation Resistance Tester Megger Tester Auto off
$ 116.85
- Description
- Size Guide
Description
Fluke 1503 Handheld Digital Insulation Resistance Tester Megger Tester Auto offDescription
Fluke 1503 Digital Insulation Resistance Tester F1503 Megger Meter F-1503 NEW
Description:
The Fluke 1503 insulation tester is exquisite, compact, durable and easy to operate.
The insulation multimeter Fluke 1503 have become numerous overhauls because they can accept various test voltages.
Ideal for debugging and preventive maintenance situations.
Features:
* 0.1 MΩ to 2000 GΩ insulation test
* Insulation test voltage: 500 V and 1000 V, for a variety of applications
* The remote test probe makes it easy to perform repeated tests and perform tests in inaccessible locations
* Live circuit detection, if the detected voltage is greater than 30 V, the test ban to improve the protection of personnel
* Capacitive voltage automatic discharge function and improve the protection of personnel
* AC / DC voltage: 0.1 V to 600 V
* 200 mA Continuity measurement
* Resistance: 0.01 Ω to 20.00 KΩ
* Auto off function to save battery power
* CAT IV 600 V measurement level of security, improved protection of personnel
* Included Accessories: Remote probe, test leads and probes, alligator clips
* Install the optional Fluke TPAK magnetic suspension system so you can free up your hands for other work
* 4 AA alkaline batteries (NEDA 15 A or IEC LR6), at least 1000 insulation tests can be (not include Package)
Specification:
Condition: 100% Brand New
Item Type: Insulation Resistance Tester
Material: ABS
Color: As shown in the picture
AC/DC voltage measurement
Accuracy
Range
600.0 V
Resolution
0.1 V
50 Hz to 400 Hz ±(reading % +digits)
±(2% + 3)
Input impedance
3 MΩ(nominal), < 100 pF
Attenuation common-mode (1 k Ω imbalance)
DC > 60 dB, 50 or 60 Hz
Overload protection
600 V rms or DC
Grounding connection resistance measurement
Range/resolution
20.00 Ω
0.01 Ω
200.0 Ω
0.1 Ω
2000 Ω
1.0 Ω
20.00 kΩ
0.01 kΩ
Accuracy
±(1.5% + 3)
Overload protection
2 V rms or DC
Open circuit test voltage
> 4.0 V, < 8 V
Short-circuit current
> 200.0 mA
The insulation specification
Measurement range
0.01 MΩ to 2000 MΩ
Testing voltage
500 V,1000 V
Test voltage accuracy
+ 20%, - 0%
Short-circuit current
1 mA(nominal)
Self discharge
Discharge time < 0.5 seconds, C = 1 µF or less
Live circuit indicator
Before initializing the test, if the terminal voltage is > 30 V, conduct the suppression test
Maximum capacitive load
The load can be operated under 1 µF
Measurement accuracy
500 V
±(1.5% + 5)
1000 V
Below 2000 MΩ ,±(1.5% + 5), Above2000 MΩ, ±(10% + 3)
General technical index
Maximum voltage applied to any terminal
600 V AC rms or DC
Storage temperature
-40 °C to 60 °C(-40 °F to 140 °F)
Operating temperature
-20 °C to 55 °C(-4 °F to 131 °F)
Temperature coefficient
When temperature < 18 °C or > 28 °C(< 64 °F or > 82 °F), 0.05x (specified accuracy)/°C
Relative humidity
10 °C to 30 °C(50 °F to 86 °F), 0% to 95%
30 °C to 40 °C(86 °F to 104 °F), 0% o 75%
40 °C to 55 °C(104 °F to 131 °F), 0% to 40%
Vibration
Random, 2 g, 5-500 Hz, according to mil-prf-28800f 2 class instrument
Impact
1 meter drop as per IEC 61010-1, 2nd version (1 meter drop test, 6 sides, oak floor)
Electromagnetic compatibility
Accuracy = specified accuracy in a 3 V/M rf magnetic field (EN 61326-1:1997)
Security
According to ANSI/ISA 82.02.01 (61010-1) 2004, CAN/ csa-c22.2 NO. 61010-1-04, and IEC/EN 61010-1, 2nd version, class IV measurement 600 V (CAT IV)
Certificate
CSA according to the standard CSA/CAN C22.2 No. 61010.1-04; TUV is in accordance with the standard IEC/EN 61010-1, 2nd version
Battery
4 x AA batteries (NEDA 15A or IEC LR6) (not included)
Battery life
Insulation test purpose
At room temperature, the new alkaline battery can perform at least 1,000 insulation tests on the instrument. The results of the standard is in 1000 V through 1 M Ω resistance measured, under the condition of the cycle time for 5 seconds, 25 seconds.
Resistance measurement
At room temperature, the new alkaline battery can be used for at least 2500 grounding connection insulation measurements. The results of the standard is in the case of 1 Ω resistance measured, the cycle time for 5 seconds, 25 seconds.
Size(H x W x L)
5.0 x 10.0 x 20.3 cm /1.97 x 3.94 x 8.00 in
Weight
550 g /1.2 lb
IP protection grade
IP40
Altitude
Working altitude
2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operational (storage)
12000 m
Excess capacity
110% range
Package List:
1 x Insulation Resistance Tester
2 x TL224 Test Probe
2 x Test Line
1 x TP74 Test Probe
2 x Alligator Clips
1 x English Manual
Payment and Shipping
1.We accept PayPal only.
2. We will ship your item(s) within 1 working day.
Package includes
Package List:
1 x Insulation Resistance Tester
2 x TL224 Test Probe
2 x Test Line
1 x TP74 Test Probe
2 x Alligator Clips
1 x English Manual
On Dec-04-20 at 11:07:11 PST, seller added the following information: