-40%

Fluke 116/323 HVAC Combo Kit

$ 147.81

Availability: 100 in stock
  • Condition: New
  • All returns accepted: ReturnsNotAccepted

    Description

    Click on the large photo to see all 11.
    Includes:
    Fluke 116
    Fluke 323
    Fluke TL175 TwistGuard test leads
    Fluke 80PK-1 bead Thermocouple
    Fluke 80PK-11 Type-K Flexible Cuff Thermocouple
    Fluke 80AK-A Thermocouple Adapter
    Fluke Tpak magnetic holder for the 116
    Fluke C115 soft case
    Fluke user manuals
    Fluke 116 Digital Multimeter
    Built-in thermometer for HVAC applications
    Microamps to test flame sensors
    Low input impedance: helps prevent false readings due to ghost voltage
    Large white LED backlight to work in poorly lit areas
    Resistance, continuity, frequency, capacitance and temperature
    Min / Max / Average with elapsed time to record signal fluctuations
    Compact ergonomic design for one-handed operation
    CAT III 600 V safety rated
    Fluke 323 True-rms Clamp Meter
    400 A AC current measurement
    600 VAC and DC voltage measurement
    True RMS AC voltage and current for accurate measurements on non-linear signals
    Resistance measurement up to 40 kΩ with continuity detection
    CAT IV 300 V/CAT III 600 V safety rating
    Fluke 116 HVAC Multimeter with Temperature and Microamps
    Specifications
    Maximum voltage between any terminal and earth ground     600 V
    Surge protection     6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
    Display     6,000 counts, updates 4 per second
    Bar graph     33 segments, updates 32 per second
    Operating temperature     -10°C to +50°C
    Storage temperature     -40°C to +60°C
    Battery type     9 volt Alkaline
    Battery life     400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts     Range/Resolution     600.0 mV / 0.1 mV
    Accuracy     ±([% of reading] + [counts]): 0.5% + 2
    DC volts
    Range / Resolution
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy     ±([% of reading] + [counts]): 0.5% + 2
    Auto volts
    Range / Resolution
    600.0 V / 0.1 V
    Accuracy     2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts¹ True RMS
    Range/Resolution
    600.0 mV / 0.1 mV
    Accuracy     1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts¹ True RMS
    Range/Resolution
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy     1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity
    Range/Resolution
    600 Ω / 1 Ω
    Accuracy     Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
    Ohms
    Range/Resolution
    600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy     0.9% + 1
    Range/Resolution
    40.00 MΩ / 0.01 MΩ
    Accuracy     1.5% + 2
    Diode test
    Range/Resolution
    2.000 V / 0.001 V
    Accuracy     0.9% + 2
    Capacitance
    Range/Resolution
    1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy     1.9% + 2
    Range/Resolution
    > 1000 μF
    Accuracy     5% + 20%
    LoZ capacitance
    Range     1 nF to 500 μF
    Accuracy     10% + 2 typical
    Temperature² (Type-K thermocouple)
    Range/Resolution
    -40°C to 400°C / 0.1°C
    Accuracy     1% + 10²
    Range/Resolution
    -40°F to 752°F / 0.2°F
    Accuracy     1% + 18²
    Includes 80PK-1 ( K-Type thermocouple bead probe ) –40 to +260 C ( -40 to +500 F )
    AC μamps True RMS (45 Hz to 500 Hz)
    Range/Resolution
    600.0 μA / 0.1 μA
    Accuracy     1.0% + 2
    DC μamps
    Range/Resolution
    600.0 μA / 0.1 μA
    Accuracy     1.0% + 2
    Hz (V or A input)²
    Range/Resolution
    99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
    Accuracy     0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    • Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    • Temperature Range/Resolution: -40°F to 752°F / 0.2°F
    Mechanical and General Specifications
    Size     167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight     550 g
    Fluke 323 True-rms Clamp Meter
    Specifications
    AC current     Range     400.0 A
    Accuracy     2% ±5 digits
    (45 Hz to 65 Hz)
    2.5% ±5 digits
    (65 Hz to 400 Hz)
    AC voltage     Range     600.0 V
    Accuracy     1.5% ±5 digits
    DC voltage     Range     600.0 V
    Accuracy     1.0% ±5 digits
    Resistance     Range/Resolution     400.0 Ω/ 4000 Ω
    Accuracy     1.0% ±5 digits
    Continuity     ≤ 70 Ω
    AC response     True-rms
    Data hold     Yes
    Size     H x W x D (mm)     207 x 75 x 34
    Max wire diameter     30 mm (600 MCM)
    Weight     265 g
    Category rating     CAT III 600 V
    CAT IV 300 V
    Fluke 80PK-1 Bead Probe Thermocouple
    Specifications
    Type     K special grade
    Measurement Range     -40 to 500°F (-40 to 260°C) continuous
    Accuracy (with Respect to NBS Tables for Special Grade)     ±2.0°F (1.1°C) over the range of 32 to 500°F (0 to 260°C)
    Fluke 80PK-11 Type-K Flexible Cuff Thermocouple Temperature Probe
    Specifications
    Measurement range    -30°C to 150°C (-19.3°F to 302°F)
    Accuracy    ±1.5°C (±2.7°F)
    Measurement time (time constant)    10 seconds
    Maximum voltage    24 V AC rms or 60 V DC maximum for proper safe operation.
    Maximum temperature    150°C (302°F)
    Cable    Total length    1 m (40 in), 0.97 m (38 in) lead wire, 49.5 cm (19.5 in) fabric hook-and-loop fastener cuff
    Insulation material    Hytrel
    Width of attachment material    2.5 cm (1 in)
    Min usable pipe diameter    3.8 cm (1.5 in)
    Max. usable pipe diameter    14 cm (5.5 in)
    Connector    Type    Yellow mini-thermocouple with 0.500 in pin
    Material    Hytrel 4774
    Maximum temperature    200°C (392°F)
    Fluke 80AK-A Thermocouple Adapter
    Adapts Type-K thermocouple mini-connector to dual shrouded banana plug inputs
    Measurement range and accuracy probe dependent
    Suitable for low voltage applications (below 30 V AC, 60 V DC)