-40%
Fluke 116/323 HVAC Combo Kit
$ 147.81
- Description
- Size Guide
Description
Click on the large photo to see all 11.Includes:
Fluke 116
Fluke 323
Fluke TL175 TwistGuard test leads
Fluke 80PK-1 bead Thermocouple
Fluke 80PK-11 Type-K Flexible Cuff Thermocouple
Fluke 80AK-A Thermocouple Adapter
Fluke Tpak magnetic holder for the 116
Fluke C115 soft case
Fluke user manuals
Fluke 116 Digital Multimeter
Built-in thermometer for HVAC applications
Microamps to test flame sensors
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
Resistance, continuity, frequency, capacitance and temperature
Min / Max / Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
CAT III 600 V safety rated
Fluke 323 True-rms Clamp Meter
400 A AC current measurement
600 VAC and DC voltage measurement
True RMS AC voltage and current for accurate measurements on non-linear signals
Resistance measurement up to 40 kΩ with continuity detection
CAT IV 300 V/CAT III 600 V safety rating
Fluke 116 HVAC Multimeter with Temperature and Microamps
Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Battery type 9 volt Alkaline
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/Resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts
Range / Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts
Range / Resolution
600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS
Range/Resolution
600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS
Range/Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/Resolution
600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/Resolution
40.00 MΩ / 0.01 MΩ
Accuracy 1.5% + 2
Diode test
Range/Resolution
2.000 V / 0.001 V
Accuracy 0.9% + 2
Capacitance
Range/Resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution
> 1000 μF
Accuracy 5% + 20%
LoZ capacitance
Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature² (Type-K thermocouple)
Range/Resolution
-40°C to 400°C / 0.1°C
Accuracy 1% + 10²
Range/Resolution
-40°F to 752°F / 0.2°F
Accuracy 1% + 18²
Includes 80PK-1 ( K-Type thermocouple bead probe ) –40 to +260 C ( -40 to +500 F )
AC μamps True RMS (45 Hz to 500 Hz)
Range/Resolution
600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps
Range/Resolution
600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)²
Range/Resolution
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40°F to 752°F / 0.2°F
Mechanical and General Specifications
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Fluke 323 True-rms Clamp Meter
Specifications
AC current Range 400.0 A
Accuracy 2% ±5 digits
(45 Hz to 65 Hz)
2.5% ±5 digits
(65 Hz to 400 Hz)
AC voltage Range 600.0 V
Accuracy 1.5% ±5 digits
DC voltage Range 600.0 V
Accuracy 1.0% ±5 digits
Resistance Range/Resolution 400.0 Ω/ 4000 Ω
Accuracy 1.0% ±5 digits
Continuity ≤ 70 Ω
AC response True-rms
Data hold Yes
Size H x W x D (mm) 207 x 75 x 34
Max wire diameter 30 mm (600 MCM)
Weight 265 g
Category rating CAT III 600 V
CAT IV 300 V
Fluke 80PK-1 Bead Probe Thermocouple
Specifications
Type K special grade
Measurement Range -40 to 500°F (-40 to 260°C) continuous
Accuracy (with Respect to NBS Tables for Special Grade) ±2.0°F (1.1°C) over the range of 32 to 500°F (0 to 260°C)
Fluke 80PK-11 Type-K Flexible Cuff Thermocouple Temperature Probe
Specifications
Measurement range -30°C to 150°C (-19.3°F to 302°F)
Accuracy ±1.5°C (±2.7°F)
Measurement time (time constant) 10 seconds
Maximum voltage 24 V AC rms or 60 V DC maximum for proper safe operation.
Maximum temperature 150°C (302°F)
Cable Total length 1 m (40 in), 0.97 m (38 in) lead wire, 49.5 cm (19.5 in) fabric hook-and-loop fastener cuff
Insulation material Hytrel
Width of attachment material 2.5 cm (1 in)
Min usable pipe diameter 3.8 cm (1.5 in)
Max. usable pipe diameter 14 cm (5.5 in)
Connector Type Yellow mini-thermocouple with 0.500 in pin
Material Hytrel 4774
Maximum temperature 200°C (392°F)
Fluke 80AK-A Thermocouple Adapter
Adapts Type-K thermocouple mini-connector to dual shrouded banana plug inputs
Measurement range and accuracy probe dependent
Suitable for low voltage applications (below 30 V AC, 60 V DC)